FIRETIGHT FUSE
An OPEN STATE CAVITY BARRIER FOR VENTILATED FACADE SYSTEMS
FIRETIGHT® FUSE by Alert is a patented fire stop / cavity barrier specifically designed for fire protection of ventilated façade systems.
The Fuse consists of compressed water repellent Rockwool Rockfit Premium held between two connected cement fiber panels, allowing airflow and draining of moisture within the façade construction.
These panels are held together by special pre-tensioned fuses. In the event of a fire and the trigger temperature in the fuse (140°C) is exceeded, these fuses melt, causing the compressed stone wool to expand and completely seal the opening against fire and hot smoke. The Fuse is equipped with a reactive intumescent tape on the front and back to fully seal any irregularities in the construction against fire.
For closed / unventilated façade systems we recommend using FIRETIGHT Fire stop.
FIRE RESISTANCE OF
+60 MINUTES
FIRETIGHT® FUSE ADVANTAGES:
- A high fire resistance (60+ minutes)
- Tested fire resistance for air gaps up to 50mm
- Fast and easy installation – No need for additional brackets or glue
- Durable fire safety, no degradation of performance
- Installation without waste, easy to separate at demolition
- fCan be used both vertical and horizontally
FIRETIGHT® FUSE
APPLICATIONS
FIRETIGHT® FUSE is a cavity barrier for passive fire protection of ventilated facade systems. With FIRETIGHT® FUSE the construction is ventilated until the event of a fire causes a quick firetight seal between building components.FIRETIGHT® FUSE is used (as a cavity barrier) in buildings were the requirements for fire resistance are high such as high-rise buildings, hospitals, public buildings, etc.
Tested by
Efectis Nederland BV
Tested according to
The fire resistance is tested according the (pre-norm) prEN 1364-6:2016. “Determination of the fire resistance of non-loadbearing building elements – Part 6: Fire-resistant cavity sealing (Cavity Barriers).“
Both the cement fiber panels and the Rockwool stone wool base materials have the highest fireclass (A1).
FIRETIGHT® specifications
CHARACTERISTICS | DESCRIPTION |
---|---|
Length | 1000 mm |
Height | 150 mm |
Thickness uncompressed | Thickness of used façade insulation + thickness of the airgap (max 50mm) + excess (+/- 50 mm) |
Thickness compressed | Thickness of used façade insulation, specify when ordering / requesting quote |
Fire resistance | + 60 minutes |
Need more details about
FIRETIGHT® FUSE?
'S-GRAVELANDSEWEG 246
3125 BK SCHIEDAM THE NETHERLANDS
+31(0)10 – 30 20 200
verkoop@alertisolatie.nl
© ALERT INSULATION 2018, All right reserved